- Electrode dimension:φ9x145mm
- Electrode impedance:≤10KΩ
- Flow rate at the interface:≤0.05ml/10 min
- A solution in the salt bridge: saturated K2SO4 solution
OPTO ELECTROCHEMICAL CELL QUARTZ CELL (SS933)
Enhance your research capabilities with our Opto Electro-Chemical Cell Quartz Cell (SS933). Specifically designed for combined electrochemical and optical studies, this cell ensures precision and reliability in advanced research applications.
*Size
30*30*30MM
40*40*40MM
50*50*50MM
The electrodes shown in the picture are not included in this cell.
The electrodes inserted into this cell should be advised so that we can make suitable holes on the Teflon cap.
Applications and Specifications
Explore the versatile applications and specifications of our Opto Electro-Chemical Cell Quartz Cell (SS933). Designed for combined electrochemical and optical studies, this cell ensures accurate and reliable results in various research settings.
Related products
GOLD WORKING ELECTRODE (SS923)
Gold electrodes behave similarly to platinum but have limited usefulness in the positive potential range due to the oxidation of its surface. It has been very useful, however, for the preparation of modified electrodes containing surface structures known as self-assembled monolayers (SAMs). Elevate your electrochemical applications with our Gold Working Electrode (SS923). Meticulously crafted for superior performance, this electrode is the ideal choice for professionals seeking reliability and accuracy in their work.
*Size
Ø2mm
Ø3mm
Inquire Now
WhatsApp us
CELL STANDS (SS940)
Enhance your laboratory convenience with our high-quality Cell Stands (SS940). Meticulously crafted for reliability, these stands are the ideal choice for researchers and professionals seeking stable support for their experimental setups.
Base: carbon steel
This cell stand matches to CS930 4-neck glass cell
(the stand does not include the cell, electrodes showing in the pic.)
Inquire Now
WhatsApp us
COATING EVALUATION CELL (SS934)
Elevate your coating analysis with our high-quality Coating Evaluation Cell (SS934). Meticulously crafted for superior performance, this cell is the ideal choice for researchers and professionals seeking reliability and accuracy in their coating evaluation experiments.
Inquire Now
WhatsApp us
FLAT CORROSION CELL-DOUBLE DECK (SS936)
Rated 4.00 out of 5
The SS936 flat corrosion cell gives the user a simple, easy-to-use cell for electrochemical testing of any plate specimen larger than 1 cm2. The user can disassembles and reassembles quickly and easily. Elevate your corrosion studies with our high-quality Flat Corrosion Cell-Double Deck (SS936). Meticulously crafted for superior performance, this cell is the ideal choice for researchers and professionals seeking reliability and accuracy in their corrosion experiments.
Inquire Now
WhatsApp us
PLATINUM MICRO ELECTRODE
Elevate your research with our Platinum Micro Electrode. Designed for micro-scale applications, this electrode provides precision and reliability for advanced studies and analytical measurements.
10μm/25μm Pt microelectrode
12.5μm/25μm Au microelectrode
Inquire Now
WhatsApp us
FTO GLASS SHEETS
Elevate your research with our high-quality FTO Glass Sheets. Meticulously crafted for superior performance, these sheets are the ideal choice for researchers and professionals seeking reliability and accuracy in photovoltaic and electrochemical applications.
- Specified resistivity – (≤10 ohms/sq) or (~7ohms/sq) or (~15 ohms/sq)
- Typical resistivity – (9-11 ohms/sq) or (7- 8 ohms/sq) or (12 – 15 ohms/sq)
- The transmittance at 550nm – ≥ 79%
- FTO film Thickness – (1800-2000 Å) or (1400-1500 Å)
- Haze – ≤ 9%
- Configuration – FTO on Glass
- Substrate – Soda-lime Float glass
- Surface finished of glass – Single-Sided polished
- Passivation layer – NO
- FTO coating method – Spray pyrolysis method
Inquire Now
WhatsApp us
GLASSY CARBON WORKING ELECTRODE (SS920)
Rated 2.80 out of 5
Glassy carbon is widely used as electrode material in electrochemistry, for high-temperature crucibles, and as a component of some prosthetic devices.RVC foam is a strong, inert, electrically and thermally conductive, and corrosion-resistant porous form of carbon with a low resistance to gas and fluid flow. Elevate your electrochemical studies with our Glassy Carbon Working Electrode (SS920). Meticulously crafted for superior performance, this electrode is the ideal choice for professionals seeking reliability and accuracy in their work.
*Size
Ø2mm
Ø3mm
Ø4mm
Ø5mm
Inquire Now
WhatsApp us
ITO Glass Sheet-SITOS005
Elevate your optoelectronic projects with our high-quality ITO Glass Sheet-SITOS005. Meticulously crafted for superior performance, this glass sheet is the ideal choice for researchers and professionals seeking reliable and transparent materials for their projects.
Length x Width x Thickness: 100mm × 100mm × 1.1mm
Thickness(mm): 1.1mm
Surface Resistivity: ~10 ohms/sq
Transmittance(%): >79
Inquire Now
WhatsApp us
ELECTROCHEMICAL H-CELLS (SS932) SEALED
SS932-S H-cells(sealed)
Volume: 50~250Ml(each cell) 50ml is easy to make.
PTFE caps
Feature: The two cells are separated by an ion membrane which is prepared by the user. Ion membrane can be replaced quickly.
Applications: different solutions in anode and cathode, and should not be mixed. Sealing system. In the middle, there should be a membrane such as Nafion to avoid interference.
The customers should let us know how many electrodes to be inserted in each cell and the outer diameter of them, then we will make accordingly.
Inquire Now
WhatsApp us
MERCURY/MERCUROUS SULFATE ELECTRODE (SS903)
Elevate your electrochemical precision with our Mercury/Mercurous Sulfate Electrode (SS903). Meticulously crafted for superior performance, this electrode is the ideal choice for professionals seeking reliability and accuracy in their work.
Hg2SO4 + 2e = 2Hg + SO4 2-
E°= 0.64V vs. NHE at 25℃
Specifications
Notes
1. Please remove the cap before the first use.
2. If there are air bubbles trapped in the chamber, please swing the electrode body to remove air bubbles.
3. Please fill with saturated K2SO4 solution if the solution inside the electrode is at a low level.
4. After use, please dip the electrode into saturated K2SO4 solution.
Inquire Now
WhatsApp us
ELECTROCHEMICAL CELLS H CELLS (SS932) NOT-SEALED
SS932-2 H-cells (not sealed)
Volume: 10~500mL(each cell, the volume can be customized). 50ml most commonly chosen by customers.
PTFE cap;
Features: The two cells are separated by an ion membrane which is prepared by user. Ion membrane can be replaced quickly.
Application: different solutions in anode and cathode, and should not be mixed. Not require sealing. In the middle there should be membrane such as Nafion to avoid interference.
The customers should let us know how many electrodes to be inserted in each cell and the outer diameter of them, then we will make accordingly.
Inquire Now
WhatsApp us
CELL STAND (SS941)
Enhance your laboratory convenience with our high-quality Cell Stands (SS941). Meticulously crafted for reliability, these stands are the ideal choice for researchers and professionals seeking stable support for their experimental setups.
Inquire Now
WhatsApp us
Burma Dunnings –
I’ve been browsing online more than three hours nowadays, but I by no means found any interesting article like yours. It’s beautiful value enough for me. In my opinion, if all web owners and bloggers made good content as you did, the net might be much more useful than ever before.
http://www.tlovertonet.com/
Pierre Stodder –
What i do not understood is actually how you’re not really much more well-liked than you may be right now. You are very intelligent. You recognize thus significantly on the subject of this matter, made me individually believe it from numerous varied angles. Its like men and women aren’t fascinated unless it is one thing to accomplish with Girl gaga! Your own stuffs excellent. Always care for it up!
https://www.zoritolerimol.com