- Electrode dimension:φ9x145mm
- Electrode impedance:≤10KΩ
- Flow rate at the interface:≤0.05ml/10 min
- A solution in the salt bridge: saturated K2SO4 solution
“GLASSY CARBON WORKING ELECTRODE (SS920)” has been added to your cart. View cart
PLATINUM PLATE ELECTRODE(SS911)
Pt size can be customized.
- 10*10*0.1mm,
- 10*10*0.2mm,
- 20*20*0.1mm,
- 20*20*0.2mm
Applications and Specifications
Explore the versatile applications and specifications of our Platinum Plate Electrode (SS911). Designed for precision in electrochemical experiments, ensuring reliable results in various research settings.
Related products
HG/HGO REFERENCE ELECTRODE (SS902)
-
Elevate your electrochemical measurements with our HG/HGO Reference Electrode (SS902). Meticulously crafted for superior performance, this electrode is the ideal choice for professionals seeking reliability and accuracy in their work.HgO + H2O + 2e = Hg + 2OH–Eo = 0.098V vs. NHE at 25℃You may freely change the solution by taking off the side cover.
Inquire Now
WhatsApp us
CARBON NANOTUBES
Elevate your projects with our high-quality Carbon Nanotubes. Meticulously crafted for superior performance, these nanotubes are the ideal choice for researchers and professionals seeking cutting-edge materials for their advanced applications.
1g
Inquire Now
WhatsApp us
ELECTRODE CLAMP (SS945)
An electrode holder, commonly called a stinger, is a clamping device for holding the electrode securely in any position. The welding cable attaches to the holder through the hollow insulated handle. Each holder is designed for use within a specified range of electrode diameters and welding current.
Inquire Now
WhatsApp us
MERCURY/MERCUROUS SULFATE ELECTRODE (SS903)
Elevate your electrochemical precision with our Mercury/Mercurous Sulfate Electrode (SS903). Meticulously crafted for superior performance, this electrode is the ideal choice for professionals seeking reliability and accuracy in their work.
Hg2SO4 + 2e = 2Hg + SO4 2-
E°= 0.64V vs. NHE at 25℃
Specifications
Notes
1. Please remove the cap before the first use.
2. If there are air bubbles trapped in the chamber, please swing the electrode body to remove air bubbles.
3. Please fill with saturated K2SO4 solution if the solution inside the electrode is at a low level.
4. After use, please dip the electrode into saturated K2SO4 solution.
Inquire Now
WhatsApp us
GOLD MICRO ELECTRODE (SS926)
Gold electrodes are widely used in electrochemistry and electroanalytical chemistry. The notable performance when used in stripping analysis of many ionic species and the extraordinary affinity of the compounds for its surface make these electrodes very suitable for many applications. Elevate your microscale studies with our Gold Micro Electrode (SS926). Meticulously crafted for superior performance, this microelectrode is the ideal choice for professionals seeking reliability and accuracy in their microelectrode studies.
Inquire Now
WhatsApp us
NAFION 117 SOLUTION
Nafion™ 117 solution can be used in the formation of nafion membranes with properties like good water uptake (~27%) and ionic conductivity (~1.23 × 10−2 Ω−1 cm−1). Its current density at 600V for the polymer electrolyte fuel cells is ~640 mA cm−2.
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. Optimize your electrochemical studies with our Nafion 117 Solution. Meticulously formulated for superior performance, this solution is the choice for researchers and professionals seeking reliable and consistent results.
Make: Sigma Aldrich
CAS Number: 31175-20-9
Inquire Now
WhatsApp us
FLAT CORROSION CELL-DOUBLE DECK (SS936)
The SS936 flat corrosion cell gives the user a simple, easy-to-use cell for electrochemical testing of any plate specimen larger than 1 cm2. The user can disassembles and reassembles quickly and easily. Elevate your corrosion studies with our high-quality Flat Corrosion Cell-Double Deck (SS936). Meticulously crafted for superior performance, this cell is the ideal choice for researchers and professionals seeking reliability and accuracy in their corrosion experiments.
Inquire Now
WhatsApp us
COATING EVALUATION CELL (SS934)
Elevate your coating analysis with our high-quality Coating Evaluation Cell (SS934). Meticulously crafted for superior performance, this cell is the ideal choice for researchers and professionals seeking reliability and accuracy in their coating evaluation experiments.
Inquire Now
WhatsApp us
ELECTROCHEMICAL CELLS H CELLS (SS932) NOT-SEALED
SS932-2 H-cells (not sealed)
Volume: 10~500mL(each cell, the volume can be customized). 50ml most commonly chosen by customers.
PTFE cap;
Features: The two cells are separated by an ion membrane which is prepared by user. Ion membrane can be replaced quickly.
Application: different solutions in anode and cathode, and should not be mixed. Not require sealing. In the middle there should be membrane such as Nafion to avoid interference.
The customers should let us know how many electrodes to be inserted in each cell and the outer diameter of them, then we will make accordingly.
Inquire Now
WhatsApp us
CELL STANDS (SS940)
Enhance your laboratory convenience with our high-quality Cell Stands (SS940). Meticulously crafted for reliability, these stands are the ideal choice for researchers and professionals seeking stable support for their experimental setups.
Base: carbon steel
This cell stand matches to CS930 4-neck glass cell
(the stand does not include the cell, electrodes showing in the pic.)
Inquire Now
WhatsApp us
OPTO ELECTROCHEMICAL CELL QUARTZ CELL (SS933)
Enhance your research capabilities with our Opto Electro-Chemical Cell Quartz Cell (SS933). Specifically designed for combined electrochemical and optical studies, this cell ensures precision and reliability in advanced research applications.
*Size
30*30*30MM
40*40*40MM
50*50*50MM
The electrodes shown in the picture are not included in this cell.
The electrodes inserted into this cell should be advised so that we can make suitable holes on the Teflon cap.
Inquire Now
WhatsApp us
JACKETED ELECTROCHEMICAL CELL (SS931) NOT SEALED
Jacketed glass cell
Volume: 50mL, 100mL, 150ml
The temperature of the testing system can be controlled by the circulating water bath.
SS931 Jacketed glass cell (not sealed)
The system is not sealed. The holes on the Teflon cap can be customized according to each customer’s requirement. We will make holes on the cap according to electrodes to be used accordingly.
Discover versatility with our Jacketed Electrochemical Cell (SS931) without seal. Meticulously designed for various electrochemical experiments, this cell is ideal for applications where a sealed environment is not required.
Inquire Now
WhatsApp us
Reviews
There are no reviews yet.